A three-tone intermodulation test for transient intermodulation distortion (TIM) and related forms of dynamic nonlinearity is proposed. The test employs three tones to simultaneously produce even-order and odd-order distortion products near 1 kHz. This makes possible the use of extremely simple, yet sensitive instrumentation. A significant advantage of the test is that both stimulus and response lie in band.
Author (s): Cordell, Robert R.
Affiliation:
Bell Laboratories, Holmdel, NJ
(See document for exact affiliation information.)
Publication Date:
1981-09-06
Import into BibTeX
Permalink: https://aes2.org/publications/elibrary-page/?id=3891
(1482KB)
Click to purchase paper as a non-member or login as an AES member. If your company or school subscribes to the E-Library then switch to the institutional version. If you are not an AES member Join the AES. If you need to check your member status, login to the Member Portal.
Cordell, Robert R.; 1981; A Fully In-Band Multitone Test for Transient Intermodulation Distortion [PDF]; Bell Laboratories, Holmdel, NJ; Paper ; Available from: https://aes2.org/publications/elibrary-page/?id=3891
Cordell, Robert R.; A Fully In-Band Multitone Test for Transient Intermodulation Distortion [PDF]; Bell Laboratories, Holmdel, NJ; Paper ; 1981 Available: https://aes2.org/publications/elibrary-page/?id=3891